# Setting up Venzeo™ for fire brigades and fire safety

> Hydrants as assets with QR codes, defect alerts, inspection tasks and compliance photo requests by SMS, for fire brigades.

Source: https://help.venzeo.com/en/article/setting-up-venzeo-for-fire-brigades
Language: en
Updated: 2026-11-07

Fire brigades and fire safety technicians check hydrants, extinguishers, fire doors, vehicles and equipment, and they inspect buildings. Without structure, a check is a tick on paper. A defect found in the field can then wait weeks before anyone repairs it.

## Make each hydrant and extinguisher an asset

Create an asset for each hydrant, fire extinguisher, fire door and vehicle, with its inventory number as the custom ID. Put a QR code or NFC tag with that ID on it. Link extinguishers and fire doors to the building's place of interest, and leave vehicles without a location. Each asset then has its own history of checks. See [Tracking assets such as bins and vehicles](https://help.venzeo.com/en/article/managing-assets).

_Example: a technician scans the QR code on a hydrant, takes a photo of the open valve and picks the tag `No defect`._

## Tag the result of every check

Use tags (previously called types) for the result, such as `No defect`, `Low pressure`, `Damaged`, `Blocked access` and `Missing`. Set the result category to require at least one tag, so no check ends without a result. See [Grouping tags into categories](https://help.venzeo.com/en/article/managing-type-categories).

## Send hydrant defects to the water utility

The water utility repairs hydrants, so add a tag such as `Hydrant defect` and alert the utility on it. The recipient needs no Venzeo™ login. The alert goes out when the technician creates the report with the tag, or when someone adds the tag later. See [Activating an email alert notification](https://help.venzeo.com/en/article/activating-an-email-alert-notification).

## Plan building inspections as tasks

Create a task for each fire safety inspection of a building. Connect the building's place of interest, assign the inspector, set the expiration date and list in the description what to check. See [Creating and assigning tasks](https://help.venzeo.com/en/article/creating-and-assigning-tasks).

## Ask building managers for compliance photos by SMS

You cannot visit every building as often as the rules ask. Send the building manager a Venzeo™ Request with photo steps such as "the extinguisher label with its next service date", "the emergency exit from the inside" and "the fire door closed". The photos come back with a trusted timestamp and GPS position, so you can see the building is compliant or decide where an inspection is needed. See [Requesting photos from someone outside your team by SMS](https://help.venzeo.com/en/article/requesting-photos-by-sms).

## Follow up defects with statuses

Use statuses such as `Defect found`, `Repair ordered` and `Fixed`, so the office sees which defects are still open. Every status change stays in the report's history. See [Tracking report progress with statuses](https://help.venzeo.com/en/article/status-management).

## Which features to use

| Feature            | Use it?   | How                                                                           |
| ------------------ | --------- | ----------------------------------------------------------------------------- |
| Assets             | Yes       | Hydrants, extinguishers, fire doors and vehicles, each with a QR code         |
| Places of interest | Yes       | One per building you inspect                                                  |
| Tasks              | Yes       | One per building inspection, with an expiration date                          |
| Statuses           | Yes       | `Defect found`, `Repair ordered`, `Fixed`                                     |
| Email alerts       | Yes       | Hydrant defects to the water utility                                          |
| Projects           | Sometimes | One per incident, with the incident number as custom ID, for scene photos     |
| Venzeo™ Request    | Yes       | Compliance photos from building managers, or proof that a defect was repaired |

To send an inspection report to a building owner, see [Sharing one report via email](https://help.venzeo.com/en/article/sharing-one-report-via-email).
